Setting and monitoring the beehive scales via SMS

Odoo obrázok a textový blok

By these SMS commands, it is possible to set and monitor beehive scales FILIP. The commands are entered by sending an SMS to the telephone number of beehive scales. SIM card must be activated!

For easing of writing of SMS, the scales does not distinguish in received SMS orders between capital letters and lower case letters, as for example the command SET can have following forms: SET, Set,  SeT,  set, ...

By writing the telephone numbers in the text of the SMS, it is necessary to enter the area code of the country for relevant phone number. This number will be displayed in following format: +XXX

Values of the temperature T and humidity H in the SMS reply will be displayed only by connected sensors for measuring of mentioned parameters.

SMS from phone to FILIP
Examples. 
Description  SMS FILIP of the phone.
Examples. 
LS=1 Language setting: 0 – English, 1 – Slovak, 2 – Czech, Support for 16 language.
FILIP: The language is set
TEL=1,1AA3 Setting of phone numbers in positions 1 through production code.
Modem: Phone number is set

TEL=1,+491635123456 

TEL=5,+4219089876543

Position adjustment (1-5) and phone number. number +421 - code country.
Modem: Phone number is set
TEL=2,0 Deleting a preset phone number 2 of the memory scales.
Modem: Phone number is set
TEL List Position Telephone numbers (only show the positions with set tel. Number).
Modem: TELEPHONE NUMBERS: 1, +XXXxxx402174*2, +XXXxxx247574 *3, +XXX000000000
V Listing manufacturing data.
FILIP: Version:Beehive:1*UM-G-B*v1*UMB-00400001AB5*UMB-004.00.00001AB5*Boot-WEB*v4.5*Image-Beehive*v3.17.305*2014.5.12* www.operchip.com*NOW-OS-v1.00*1*
SQ Listing of signal quality GSM network.
FILIP: Signal quality: 65.0%
Warning for weak signal GSM network.
FILIP: Signal strenght 30.0%
TIME=DDMMRR,HHMMSS Setting the date, time:DD = day, MM = month, YY = yearHH = hour, MM = minute, SS = seconds FILIP: Time is set

TZ=+3

TZ=0

TZ=-1

Setting the time zone GMT + 3 hours, GMT or GMT + 1 hour. These can be seen only with activated time synchronization over the Internet. Command "NTPE".
FILIP: Time zone is set
TZ Get time zone.
FILIP: Time zone: GMT+3
NTPE Switching on the time synchronization using NTP over the internet.
FILIP: NTP enable
NTPD Disabling time synchronization using NTP over the internet.
FILIP: NTP disable
NTP=3.sk.pool.ntp.org Set NTP server.
FILIP: NTP server is set
NTP List settings for NTP time synchronization over the Internet.
FILIP: NTP server: Disable, 3.sk.pool.ntp.org

APN=1,internet,meno,heslo

APN=1,internet,meno

APN=1,internet

Internet connection settings to position 1. There are four positions.
FILIP: APN is set
WON Turning on the Internet (sending data).
FILIP: WEB active
WOFF Turning off the Internet (sending data)
FILIP: WEB off
EON Enable e-mails.
FILIP: Email active
EOFF Disable e-mails.
FILIP: Email off
EMAIL=1,info@operchip.com Setting up e-mail at position 1. 5 positions.
FILIP: Email is set
EMAIL=1,0 Deleting the e-mail 1 of the scale memory.
FILIP: Email is set
EMAIL Listing email settings.
FILIP: Email: 1,info@operchip.com
AON Enabling sending alarm messages.
FILIP: ALARM active
AOFF Disabling sending alarm messages.
FILIP: ALARM off
ACCON Enabling accelerometer. They must also be enabled alarms.
Accelerometer: Enable
ACCOFF Disabling accelerometer.
Accelerometer: Disable
ACC=2,250,100,0 Setting parameters of the accelerometer. Sensitivity: 2 g; The level of activation: 250mg; ODE: 100Hz; Duration: 0ms
Accelerometer: Parameters is set
ACC

Listing of set parameters accelerometer.Sensitivity: 2 g, 4 g, 8 g, 16 g

The level of activation: in milligramsODE: measurement speed.

Accelerometer: Enable, Sensitivity 16g, Threshold 5000 mg, ODR 100Hz, Duration 0 ms, Read ok
Alarm from the accelerometer. Activated when moving equipment.
Accelerometer: Active
CR=1,*100#* Setting the phone number for the automatic detection of the amount of credit in positions 1 to 4. Position 1 is universal.
Modem: Tel credit is set
CR Credit status.
TEXT – Podľa operátora  Modem: Credit: unknown
Event of insufficient credits.
Modem: Credit is 2,00 EUR
INFO Current status: W-weight, external temperature T, T2 - external temperature, humidity H, Battery - battery capacity.
FILIP: W=40,1kg*T=22,3C* T2=22,4C *H=56.0 %*Battery=91,3 %
SMSON Enabling sending SMS Info.
FILIP: SMS active
SMSOFF Disabling sending SMS Info.
FILIP: SMS off
SMS=1,0700 Position adjustment (1-8) and time sending SMS info.
FILIP: SMS is set
DSMS=1 Deleting individual (1-8) SMS Info.
FILIP: SMS deleted
SMS Summary Exposure to Time Info SMS - Active SMS Info.
FILIP: SMS:1,07:00:00* 2,13:00:00* 3,19:00:00*
SMS by set times as an information SMS.
FILIP: W=40,1kg*T=22,3C* T2=22,4C *H=56.0 %*Battery=91,3 %
TIMER=60,2 TIMER -each 60 minutes recorded measurements, each 60 x 2 = 120 min activates modem.  
FILIP: Timer is set
SET Listing setup time, enable or disable alarms, SMS text, Internet, email. Adjust the timing for measuring a GSM module, the threshold for sensors and parameters for the weight of the first.
FILIP: Date 08.01.2014 09:12:00 *AlOff*SMSOn*WEBOn* Tim=15,x2* *TR=50,55* T2R=25,26*HR=60,65* WR=10,11* WR2=60,64*  Wmax=200.0 kg* Wtare=0.0 kg
SET2 Listing settings, time, weight 1, weight 2.
FILIP: Date 08.01.2014 09:12:00 * W2R=10,11* W2R2=60,64*  W2max=200.0 kg* W2tare=0.0 kg*
WA=2 Activating the number of connected weighing platforms. 1-3.
Weight: Active
WR=10,11 Range no. Weight of 1 - (kg)
Weight W: Range is set
ALARM SMS - Weight (kg).
Weight W:  ALARM 64,5 kg
WR2=60,64 Range no. Weight of 2 - (kg).
Weight W: Range is set
ALARM SMS - Weight (kg).
Weight W:  ALARM 64,5 kg
WT Entering TARA. Reset weight, although weight is on it.
Weight W: TARE is set
WCT Cancel Tara. Returns the status as to production calibration.
Weight W: TARE is canceled
W2R=10,11 Range no. Weight of 1 - (kg).
Weight W2: Range is set
ALARM SMS - Weight (kg).
Weight W2:  ALARM 64,5 kg
W2R2=60,64 Range no. Weight of 2 - (kg).
Weight W2: Range is set
ALARM SMS - Weight (kg).
Weight W2:  ALARM 64,5 kg
W2T Entering TARA. Reset weight, although weight is on it.
Weight W2: TARE is set
W2CT Cancel Tara. Returns the status as to production calibration.
Weight W2: TARE is canceled
TR=5,6 The temperature range for T – ( o C) Temperature T: Range is set
ALARM SMS – Temperature T – ( o C) Temperature T: ALARM 24,1 C
T2R=23,24 The temperature range for T2 – ( o C) Temperature T2: Range is set
ALARM SMS - Temperature T2 - ( o C) Temperature T2: ALARM 24,2 C
HR=60,65 Humidity range for H - (%).
Humidity H: Range is set
ALARM SMS – Humidity H – (%)
Humidity H: ALARM 66,1%
BR=30,100 Setting range for battery. 30% and 100% of capacity.
Battery: Range is set
Warning low voltage power accumulator.
Battery: 29,9 % Battery is low
Warning battery charge.
Battery: 70,0 %
Contakt ALARM active.
Detector 2: Active
Contact ALARM inactive.
Detector 2: End
SON Turning on the siren. The siren turns on automatically when activating the alarm contact.
Siren: Active
SOFF Turning off the siren. The siren goes off and automatically 30 seconds after activation of the alarm contacts.
Siren: Off
SAVE User settings are saved.Phone numbers, URLs on the web,Mail, Email settings, Internet settings, sender names, names errors, names of commands, responses and events.
FILIP: Save OK
LOAD Retrieving user settings.
FILIP: Load OK
CT=INFO,STATE Change text command. The first parameter is the old command, the second parameter of the new command.
Modem: Command name is set
GCT=10 Listing command text from the position in the parameter. 5 commands.
Modem: Commands: 10,CR;11,GCT=;12, CT=;13,DT=;14,AT=;
DT=Siren,Buzzer Change text sender. The first option old text, the second parameter new text.
Modem: The name is set
AT=Battery is low, Acumulator is low Change text responses to events and alarms. The first option old text, the second parameter new text.
Modem: Alarm name is set
SMS command does not exist
FILIP: Command does not exist
Wrong format of SMS command.
FILIP: Error command format
System Command !!!
WTCON Zapnutie merania automatickej korekcie hmotnosti od okolitej teploty pre hlavnú váhu. FILIP  Temperature correct active
W2TCON Zapnutie merania automatickej korekcie hmotnosti od okolitej teploty pre prídavnú váhu. FILIP  Temperature correct active
WTCOFF Vypnutie merania automatickej korekcie hmotnosti od okolitej teploty pre hlavnú váhu. FILIP  Temperature correct off
W2TCOFF Vypnutie merania automatickej korekcie hmotnosti od okolitej teploty pre prídavnú váhu. FILIP  Temperature correct off
WTC=100 Nastavenie hodnoty automatickej korekcie hmotnosti od okolitej teploty pre hlavnú váhu na 100 gramov na stupeň celzia. FILIP  Temperature correct set
W2TC=-60 Nastavenie hodnoty automatickej korekcie hmotnosti od okolitej teploty pre prídavnú váhu na -60 gramov na stupeň celzia. FILIP  Temperature correct set
WTCS Výpis stavu a nastavenej automatickej korekcie v gramoch pre hlavnú váhu. FILIP  100 gram/degree celsius
W2TCS Výpis stavu a nastavenej automatickej korekcie v gramoch pre prídavnú váhu. FILIP  -60 gram/degree celsius
US Reprogramming weight with retention of all settings. Check the current version available at http://www.operchip.com/beehive/Currently in the device detects the command "V". It must be enabled web. Command "WON. FILIP : Update Begin
UNS Reprogramming balance settings to overwrite the factory settings. Check the current version available at http://www.operchip.com/beehive/ Currently in the device detects the command "V".It must be enabled web. Command "WON". FILIP: Update Begin
WZC Calibration scales to zero. On weight must be no load.
Weight W:  Zero calibration ok
W2ZC Calibration scales 2 to zero. On weight must be no load.
Weight W2: Zero calibration ok
WVC=80000 Calibration scales to 80 kg. Must be on weight 80 kg.
Weight W: Weight calibration ok
W2VC=100000 Calibration scales to 100 kg. Must be on weight 100 kg.
Weight W2: Weight calibration ok
WM=150 Setting the maximum scales at 150 kg.
Weight W: MAXIMUM weight is set
W2M=150 Setting the maximum scales at 150 kg.
Weight W2: MAXIMUM weight is set
RESET Reset the device. It must be functional GSM module.
FILIP: Reset Device